Can I copy the parameters in my HI 3000 or HI 4000 series controllers?

How can I download all of the parameters in the HI 3000 series or HI 4000 series units so I have them if I need to set-up a replacement? Are there any parameters that do not get downloaded and need to be manually recorded? Do I need a specific software?

Why can't I communicate with the Ethernet I/P option on a HI 3000 series controller?

I have a HI 3000 series unit with the Ethernet I/P option installed. I have set up and can ping the address with good results. RS Linx also sees the unit on the network. But my Compact Logix processor shows a communications error and cannot get my unit online. What could be the problem?

Why are we getting an A/D error after we replace our old controller?

We are replacing our obsolete weight controller with a new Hardy controller and want to reuse the same load cells. Our traditional calibration methods are giving us problems when we try to set the span. I think it's because our old unit has 10 volts excitation and the Hardy unit has 5 volts excitation. When we run the mV calibration signal above 15, we get an A/D Conversion Error on our Hardy unit. Do we need to take our old calibration values and divide by 2?

Can we configure the HI 3030 printer port to send specific data upon request?

Can we configure the HI 3030 printer port to send specific data upon request?

Can I remotely set the date & time on my HI 3030 with ControlNet?

On a HI 3030 with ControlNet is it possible to set the date and time remotely through the ControlNet connection?

Why does my ControlNet communication fail on my replacement HI 3000 unit?

I have an existing system with an HI 3000 series unit on ControlNet to my PLC. My original HI 3000 series unit failed so I replaced it with a new HI 3000 unit with ControlNet, but the new unit will not communicate over the ControlNet network. What could be the problem?

Which Hardy Instrument can perform a weight totalization function?

Which Hardy Instrument can perform a weight totalization function?

Can I map a "clear tare" through software on my HI 3030?

Is it possible to map a "clear tare" through software on my HI 3030 so I can clear the tare through RSLogix? The following mapping exists through internet explorer for DeviceNet: DFO0=+HFI4, DFO2=+HFI8, DFO4=+HFO21, DIO6=+HSI3, DO7.0=+HI1.6, HO1.0=+DI0.0 This mapping equates to: DFO0(DeviceNet Float Output) = +HFI4(Gross Weight chan 1) DFO2(DeviceNet Float Output) = +HFI8(Net Weight chan 1) DFO4(DeviceNet Float Output) = +HFO21(Tare weight Chan 1) DIO6(DeviceNet Integer Output) = +HSI3(Command Status) DO7.0(DeviceNet Boolean Output) = +HI1.6(Motion) HO1.0(Tare 1 command) = +DI0.0(DeviceNet Boolean Input) Is there an instruction to clear the tare? Suggestions?

How does Rate Of Change (ROC) work?

How does Rate Of Change (ROC) work?

How do I set up tags to receive weight data over Ethernet IP?

How do I set up tags to send commands to the controller and receive weight data from my Hardy Instrument over Ethernet IP?