What is the max I/O that can I use over DeviceNet on my Hardy controller?

What is the maximum I/O that can I use in my HI 3000 or HI 4000 series over DeviceNet?  The system needs to control 4 scales and the total I/O for the four scales is 75 Outputs, 30 Inputs.

How are the HI 3010 output control functions activated?

How are the HI 3010 output control functions activated? What voltages, and between what points?

What is the response time of a HI 3000 series controller?

If I am using a 4 channel HI 3030 weight controller for a check weighing application, how long does the item being weighed need to be on the scale in order to get a good weight reading ?

What information can I access (read/write) through the DeviceNet on a 3000 or 4000 series unit?

What information can I access (read/write) through the DeviceNet network in my HI 3010, HI 3030, HI 3300, HI 3600, HI 4050 or my HI 4060?

What are the power requirements for the HI 3000 series?

What are the power requirements for the HI 3010,  or the HI 3030?

Is the HI 215IT summing board compatible with all Hardy Instruments?

We are not getting a reading from the HI 215IT junction box. The HI 215IT is connected to a HI 1771-XX-RT and from there it is connected to a HI 1771WS module using the HI 1771-XX-C6 cable. Is the HI 215IT summing board compatible with all Hardy Instruments?

How can I tell if my load cell is good without using Integrated Technician?

I am using older load cells from Hardy Process Solutions (or from another company) and I want to make sure they are functioning properly before I use them in another application. I don't have the Hardy feature "Integrated Technician" in my junction box or controller, so I checked the installation/troubleshooting guide which says to check the resistance between the signal wires and the excitation wires and the resistance of each should be around 350 ohms. Well, the resistance between the signal wires on all 8 load cells was right at 350 ohms, but the resistance between the excitation wires on all 8 load cells was around 387 ohms. So, are all of these load cells bad, or is it ok for the excitation resistance to be 387 ohms?

Using a 4-Scale HI 3030, can I see individual load cell MV readings with IT?

Can I see individual load cell MV readings with IT on a HI 3030-4S (four scale option)?

Do you have menu trees for the Filler, Dispenser and IBC controller?

Do you have menu trees for the HI 3010 Filler, Dispenser and IBC controller that would make setup easier?

Where in the computer do you install the EDS file?