You have no items in your shopping cart.

New HI6800 Weight Controller

Weight-based Application Control
HILPRE - ADVANTAGE® Lite C2® Compression Load Point (440 to 4,400 lbs)

HILPRE - ADVANTAGE® Lite C2® Compression Load Point (440 to 4,400 lbs)

The Hardy ADVANTAGE® Lite Series of load point assemblies provides superior performance when compared to common load cells, as well as exceptional value, in meeting your weighing needs.

Complete Your System

Or call 858.278.2900 for assistance

Compression Load Point Assembly

The Hardy ADVANTAGE® Lite Series of load point assemblies provides superior performance when compared to common load cells, as well as exceptional value, in meeting your weighing needs.

Each pre-assembled load point consists of rugged stainless steel mounting hardware and a C2® Calibration compatible stainless steel, mV/V, and mV/V/ohm matched and sealed load sensor.

The rubber element mount provides stray voltage isolation, minor misalignment correction, thermal expansion, and shock absorption. It can be used in applications with conveyors and vessels with or without agitators or mixers. The load point assembly is self-checking, eliminating the need for costly external check rods to hold the assembly in place and also provides lift-off protection.

Each load sensor comes with twenty feet of six-conductor cable and a color-coded wiring label to aid in installation. The sensors have an IP rating of IP67.

The ADVANTAGE Lite Series is available in the following standard capacities: 440 lb, 1,100 lb, 2,200 lb, and 4,400 lb.

Rated Output

  • (ES) 2±0.004mV/V

Non-Linearity

  • <±0.025 % R.O.

Hysteresis

  • <±0.025 % R.O.

Zero Balance

  • <±1.0 % R.O.

Creep @ 5 Min.

  • <±0.010 % R.O.

Temp Effect Output

  • <±0.002 % R.O./C

Temp Effect Sensitivity

  • <±0.002 % R.O./C

Input Resistance

  • 1100 ± 5.0% ohm

Output Resistance

  • 1000 ± 2.0% ohm

Insulation Resistance

  • >5000 Mohm

Excitation

  • 5 - 15 vdc

Safe Load Limit

  • 200 % Emax

Ultimate Load

  • 300 % Emax

Warranty

  • Two years

Specifications are subject to change without notice.

Note: Calibrated for mV/V/Ohm and mV/V, which results in “cornering” without adjustment, may eliminate the need for re-calibration after field replacement.

Capacity

Model # - HILPRE copy
Or call 858.278.2900 for assistance