Up to 30 Channels of Weight on one SINGLE Ethernet Connection!
New HI 6600 Series Modular Sensor System
The new HI 6600 series is a modular system of weight processors that
deliver up to 30 channels of fast, stable, high-resolution weight readings to PLCs, PACs and DSCs over a single fieldbus network connection.
Ideal for applications that require more than one channel of weight, such as inventory tank farms, batching systems and multi-head filling machinery; each channel of the HI 6600 processes signals from up to four connected load cells then outputs the entire system’s weight data over Ethernet TCP/IP, Modbus RTU, Modbus TCP and either EtherNet/IP or Profibus-DP, depending on the Hardy Gateway Module.
Book a One-on-One Virtual Demo to See the HI 6600 in action!
Take the HI6600 for a Test Drive. Click Here!
SOLID PERFORMANCE
The HI 6600 enhances productivity of manufacturing systems by digitally suppressing noise and dramatically reducing scale settling time. Even in noisy environments with excessive amounts of mechanical vibration, the HI 6600 provides a steady 1:10:000 resolution in oz, lb, ton, g, and kg with 110 updates per second over its variety of communications protocols.
EASY INSTALLATION
Just snap the number of weight channels you need onto a DIN rail, cable the units together to the Gateway Module using standard Cat5e cable, connect sensors, power up and press DISCOVER. The system will automatically identify all the modules connected together and make them addressable for set-up and calibration through the PLC, embedded Webserver or optional display. A Rockwell EDS_AOP simplifies integration using RSLogix.
SIMPLE SET-UP & CALIBRATION
The embedded webserver enables access to setup and calibration from anywhere on your network. An optional display adds front panel
keys, simple menus and help text to make local control elementary. Use Hardy's exclusive C2® for automatic system calibration to save hours in commissioning and routine maintenance.
QUICK MAINTENCE & DIAGNOSTICS
With INTEGRATED TECHNICIAN®, maintain and troubleshoot the weighing system from anywhere in the world or use Hardy’s intuitive local display that supports multiple languages. Store all the system parameters on a USB, clone settings between channels, and restore settings with the press of a button. Quick-disconnects on all wiring makes hot swapping damaged channels a snap!
OPTIONAL DISPLAY
Hardy’s big, bright display allows local set-up, calibration and troubleshooting of the weight system without the need to access parameters via a PC, PAC, or PLC. Basic monitoring and maintenance can be done by anyone through its IP66 rated keypad. The display can show weight from up to 28 connected weight modules, displaying up to 4 channels simultaneously. Name the weight channels for easy identification and arrange them to show in any order.
ULTRA LOW POWER CONSUMPTION
At just 1.72 watts of power per channel and 3.9 watts per Gateway Module, eliminate the cost of cooling in the control cabinet and create high-density cabinet designs to save space and money.
VIBRATION IMMUNITY
Hardy’s WAVERSAVER® supresses vibration and mechanical noise, dramatically reducing scale settling time and increasing the speed of stable weight readings.
The HI 6600 Series is available to order now! Contact your Hardy Sales Engineer or the Hardy Service Center today! 800-821-5831 or 858-278-2900. Email us at hardyinfo@hardysolutions.com
MODEL NUMBERS
HI 6600 SERIES
HI6610 Weight Processing Module, no display
HI6600-EIP HardyNet Gateway Module - EtherNet/IP
HI6600-DP HardyNet Gateway Module - Profibus-DP
HI6110 Optional Multi-Channel Display
Weight Processing Module (WPM)
Resolution
• Stable processed weight 1:10,000
• Maximum displayed resolution: 1:999,999
• Internal resolution 1:8,388,608
Update Rate
• Processed weight, display, comm: 110 times per sec.
• Unprocessed weight (A/D conversion): 4800 Hz
Modes:
• Gross, Net
Units of Measure:
• Ounce, Pound, Ton, Gram, Kg, Metric Ton
Weight Processing
• WAVERSAVER®: 0.25 Hz to 7.5 Hz
• Averaging:1 to 255 User-selectable in single increments
Calibration Methods:
• C2® calibration without test weights
• Traditional calibration with test weights
Power
HI 6610: 24 VDC, Class 2 Source, max 1.72 Watts
Excitation:
• 5VDC
Number of Load Cells:
• Up to 4 at 350 Ω per weight processing module
Hardy Gateway Module (HGM)
Expansion
• Up to 28 weight processing modules per system*
• Maximum System Span: 500 ft (150 m)*
*May require external 24VDC power. See User Guide for details.
HGM Available Protocols:
• EtherNet/IP (-EIP models)
• PROFIBUS-DP (-DP models)
• Ethernet TCP/IP (Embedded Webserver) -- all models
• Modbus RTU all models
Communication Interface:
• Terminal (serial), RJ-45
• USB setup and configuration saving
Power:
• HI 6600: 12-24 VDC, Class 2 Source, max 3.9 Watts
Common Specifications
Dimensions:
• 4.55” D x 4.75”H x 1.25” W
Housing:
• High Strength ABS-Polycarbonate Blend
Mounting:
• DIN Rail with integrated clip
Interconnect Cable:
• RJ45 / Cat5e
Temperature:
-10°C to +60°C (14° F to 160°F)
* Specific configuration information is available in the HI 6600 User's Guide
Get more information about the HI 6600 Series at www.hardysolutions.com
hardyinfo@hardysolutions.com
or 1-800-821-5831
Models
HI6610-WP Weight Processing Module, no display
HI6600-EIP HardyNet Gateway Module - EtherNet/IP
HI6600-DP HardyNet Gateway Module - Profibus-DP
HI6110 Optional Multi-Channel Display
Options
6032-0082-0 Cable Assy, Ethernet Patch, Cat 5E, 6.00" long, Black
(one per weight module)
0509-0536-10-0 Monochrome Display 10 foot display interface cable