You have no items in your shopping cart.

New HI6800 Weight Controller

Weight-based Application Control
HISPA22 - C2® Aluminum Single Point Load Cell (5 kg - 50 kg)

HISPA22 - C2® Aluminum Single Point Load Cell (5 kg - 50 kg)

The Hardy Process Solutions HI SPA Series of aluminum single point load cells are designed for the OEM, conveyor, and bench scale markets, which can accommodate off center loads. They are built to perform in industrial packaging, dispensing, and dosing applications. These aluminum sensors come standard with C2® calibration capabilities.

Complete Your System

Or call 858.278.2900 for assistance

The Hardy Process Solutions HI SPA Series of aluminum single point load cells are designed for the OEM, conveyor, and bench scale markets, which can accommodate off center loads. They are built to perform in industrial packaging, dispensing, and dosing applications. These aluminum sensors come standard with C2® calibration capabilities.

The HI SPA22 is available in capacities from 11lbs to 88lbs (5kg to 40kg), is environmentally rated at IP67, and has improved potting. The HI SPA22 has 2 meters of cable (6.5 ft.).

Capacities: 11/22/44/66/88 lbs (5/10/20/30/40 kg)

SPECIFICATIONS

HI SPA22

Rated Output (ES)

2±10% mV/V

Max # Verification Int.

3000

Min Verification Int.

Emax/6000

Non-Linearity

<±0.0166 % R.O.

Hysteresis

<±0.0166 % R.O.

Zero Balance

<±5.0 % R.O.

Combined Error

<±0.02

Creep @ 30 Min.

<±0.0166 % R.O.

Temp Effect Output

<±0.0233 % R.O./C

Temp Effect Sensitivity

<±0.010 % R.O./C

Input Resistance

413 ± 20 ohm

Output Resistance

350 ± 25 ohm

Insulation Resistance

≥5000 Mohm

Excitation

5 - 15 vdc

Safe Load Limit

150 % Emax

Ultimate Load

300 % Emax

Safe Side Load

100 % Emax

Material

Aluminum

Sealing

Potted

IP Rating

IP67

Hazardous

FM IS Class 1, Div 1

Warranty

Two years

 

Capacity

Model # - HISPA22 copy
Or call 858.278.2900 for assistance

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.

Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.

C2® (or eCAL) Electronic Calibration

The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

INTEGRATED TECHNICIAN® Operator Diagnostics

Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.