Wissensdatenbank

Filter Filter button
Results: 31 - 40 of 101

Kategorien

When I change units of measure what else do I need to change?

When I change units of measure on my Hardy weight controller, what else do I need to change?

What information can I access (read/write) through the DeviceNet on a 3000 or 4000 series unit?

What information can I access (read/write) through the DeviceNet network in my HI 3010, HI 3030, HI 3300, HI 3600, HI 4050 or my HI 4060?

How can I tell if my load cell is good without using Integrated Technician?

I am using older load cells from Hardy Process Solutions (or from another company) and I want to make sure they are functioning properly before I use them in another application. I don't have the Hardy feature "Integrated Technician" in my junction box or controller, so I checked the installation/troubleshooting guide which says to check the resistance between the signal wires and the excitation wires and the resistance of each should be around 350 ohms. Well, the resistance between the signal wires on all 8 load cells was right at 350 ohms, but the resistance between the excitation wires on all 8 load cells was around 387 ohms. So, are all of these load cells bad, or is it ok for the excitation resistance to be 387 ohms?

What is the difference between analog and digital communications?

What are the main differences between using analog or digital communications? Why is digital communications considered a better form of communications?

Do you have a manual for an old digital weight indicator?

Do you still have manuals for older digital weight indicators?

Can I have multiple scales on a single weight controller channel?

Can I have multiple scales on a single weight controller channel?

How fast is the update cycle for the 0-20 mA Output signal?

How fast is the update cycle for the 0-20 mA output signal? Is it safe enough to check the 0-20 mA signal with a PLC every second in order to receive a peak?

Can I mix different model load cells?

We have a system with 4 load cells and one load cell needs to be replaced. Do I have to use the same manufacturer and model, or can I mix different model load cells together on the same system? Will my C2 function still work?

How do I protect my controllers, systems and scales from static electricity?

What is the best way to protect my Hardy controllers, systems and scales from static electricity problems? My system locks up on a regular basis and I think it is caused by static.

What is the temperature range for the HI 2151/30WC?

Radiant heat from the sun seems to be causing the output of our HI 2151/30WC to fluctuate. This problem can be seen on our calculated flow. The flow is calculated using old data, fifteen minutes prior, minus current data multiplied by four to bring it to an hourly rate, then multiplied by one thousand to display in klbs/hr. The fluctuation is not as readily seen on the 4-20mA signal, but is definitely noticeable on the calculated flow. Does the HI 2151/30WC controllers have any history of heating problems in the electronics? We might install a heat shield to shade the instrument with a two inch air gap and increase the air flow if this will help?