Analog

Analog Communications

Hardy's Analog output option provides both 0-20mA to 4-20mA and 0-5V to 0-10V simultaneously with 16,000 counts of resolution.

Each weight controller handles analog signals a little differently.

HI 2151/30WC
The Analog Output is configured from the front panel or the serial port and set up by jumpers on the printed circuit card. The option allows the transmission of Gross, Net, Optional ROC, Peak or Total weight as 0-5V, 0-10V, 0-20mA or 4-20mA (or the reverse of these), and makes it possible to span these ranges over a portion of the weight data.

Resolution is 16,000 counts, or the number of display counts available in the range selected, whichever is less.  Both voltage and current data are available simultaneously.

HI 3030/HI 3010

Both units use a dual analog card available as an option.  Each of two Analog Outputs per option card are configured from the front panel or the embedded web server. This option allows the transmission of Gross, Net, Optional ROC or “mapped” weight as 0-5V, 0-10V, 0-20mA or 4-20mA (or the reverse of these), and makes it possible to span these ranges over a portion of the weight data. All parameters can be mapped to these Analog outputs. Each analog output can be assigned to any of the instruments four-scale channels.

HI 4050

Each of four independent Analog outputs per option card are configured from the front panel or the embedded web server. This option allows the transmission of Gross, Net, available Rate-Of-Change (ROC), or “mapped” weight as 0-5V or 0-10V over two of the outputs, and 0-20mA or 4-20mA over the other two outputs. All four outputs are independent of each other. It also is possible to span these ranges over a portion of the weight data with a resolution of 16,000 counts for each channel. All parameters can be mapped to these Analog outputs.

HI 6310
The analog 4-20mA output is directly proportional to the programmed gross, net, or count range; by setting the low value equal to 4mA and the high value equal to 20mA. These values can be set from either the front panel or the web interface.

HI 6510
The analog 4-20mA output is directly proportional to the programmed gross, net, or count range; by setting the low value equal to 4mA and the high value equal to 20mA. These values can be set from either the front panel or the web interface.

Analog Products

ANYWEIGH Bench Scales

HI 2110 Weight Indicator

HI 2151/30WC Weight Controller

HI 3010 Filler/Dispenser Controller

HI 3030 Weight Controller

HI 4050 Weight Controller

HI 4050CW Check Weighing Bundle

HI 4060 Rate Controller

HI 6310 Series of Weight Processors

HI 6510 Weight Processor