HI HLPT Tension Load Points

The Hardy HI HLPT ADVANTAGE® Series, tension load point systems are designed for use on low to medium capacity vessels when they are suspended.

Hardy HI HLPT Tension Load Cell

The Hardy HI HLPT ADVANTAGE® Series, tension load cells are designed for use on low to medium capacity vessels. Each tension load cell consists of mounting hardware and a stainless steel mV/V and mV/V/ohm matched load sensor with true hermetic sealing, C2® Electronic Calibration capabilities, onboard electronic certs, a ¼ NPT conduit adapter and twenty feet of cable.

Each tension load cell assembly is specifically designed to eliminate the effects of unwanted forces to provide exceptional accuracy. A grounding strap and fixed color code wiring label are provided with each load point. The mounting hardware is available in either stainless or zinc plated steel for capacities up to 4.5K pounds and galvanized steel in higher capacities. The load sensors have an IP rating of IP68/IP69K.

The HI HLPT is available in the following standard capacities: 225 lbs, 450 lbs, 1,125 lbs, 2.25K lbs, 4.5K lbs and 11.25K lbs.

 

 

 

Specifications

Rated Output
(ES) 2±0.002mV/V
Non-Linearity
<±0.018 % R.O.
Hysteresis
<±0.025 % R.O.
Zero Balance
<±1.0 % R.O.
Creep @ 5 Min.
<±0.010 % R.O.
Temp Effect Output
<±0.0014 % R.O./C
Temp Effect Sensitivity
<±0.0007 % R.O./C
Input Resistance
1106 ± 5 ohm
Output Resistance
1000 ± 1 ohm
Insulation Resistance
>5000 Mohm
Excitation
5 - 15 vdc
Safe Load Limit
200 % Emax
Ultimate Load
300 % Emax
Warranty
Two years

Specifications are subject to change without notice.

Options

Load Point can be ordererd with Stainless Hardware (43C) as shown

Zinc plated Hardware (-45C)

Shipping Weight for Load Point approx. 10-35 lbs, Sensor 4 lbs.

HLPT systems are also available in three point (three load points and a sensor) and four point (four load points and a sensor) versions.