HI 6020IT and HI 6020JB Junction Boxes

Hardy HI 6020 summing box distributes excitation voltage to up to four load cells and transfers each load cell’s performance characteristics and weight signals to the Hardy weighing instrument.

HI 6020IT and HI 6020JB

Junction Box and Summing Cards With or Without  Optional Integrated Technician
Stainless Steel Now with Class I, II, III, Div 1 or ATEX & IECEx Hazardous Certifications

The new Hardy HI 6020 Summing box is a critical component in a weighing system that enables use of Hardy’s core technologies - C2® electronic calibration and Integrated Technician® (IT).

Each summing box distributes excitation voltage to up to four load cells and transfers each load cell’s performance characteristics and weight signals to the Hardy weighing instrument.

A summing card with IT allows a weighing instrument operator to switch to the summing card’s internal test circuit and diagnose the entire weighing system from the front panel of the instrument or a remote location over the Internet. Individual load cells can be isolated from each other for weight and voltage readings, allowing a technician or operator to quickly and safely troubleshoot weighing system faults and anomalies.

The HI 6020 Summing box is available with a variety of options, including IT, trim pots (for non-Hardy load cells) and a NEMA 4X enclosure in stainless steel, painted steel or fiberglass. The enclosure features a thick-wall design with an interior seal for a long lasting, robust wash-down installation. Each box comes with six packaged hole plugs and six cable grip fittings suitable for load cell cables with an outside diameter of 1/4 to 3/8 inches.  The ATEX and IECEx (-EX models) are designed for installation with intrinsic barriers and do not come with any glands or hole plugs. 

A single HI 6020 Summing Box supports up to 4 load cells.  To connect two HI 6020 Summing Boxes together to support between 5 and 8 load cells, use the TB6 Auxiliary connection between boxes and order one of the summing boxes with six holes. 

The HI 6020 Junction Box is UL and CE compliant and is rated for installation in Hazardous Locations:

  • HI6020IT-SSX-Y and HI6020JB-SSX-Y: USL/CNL Class I,
    II, III, Div 1 Groups ABCDEFG intrinsically safe per drawing
    0594-0007 and 0594-0008

  • HI6020JB-SSX-Y-EX and HI6020IT-SSX-Y-EX models:
    ATEX & IECEx Ex ia IIC T4 intrinsically safe per drawing
    0594-0011 and 0594-0012 ATEX Certificate No. DEMKO
    17 ATEX 1819; IECEx Certificate No. IECEx UL 17.0009

  • HI6020IT and HI6020JB: USL/CNL Class I, II, III, Div 2,
    Groups ABCDFG (except -EX versions)

Max number of Load Cells
• 8 (with two junction boxes)
Enclosure
• Choice of None, Stainless Steel, Painted Steel or Fiberglass
Hazardous Area Certifications
• HI6020IT-SSX-Y and HI6020JB-SSX-Y: USL/CNL Class I,
II, III, Div 1 Groups ABCDEFG intrinsically safe per drawing
0594-0007 and 0594-0008
• HI6020JB-SSX-Y-EX and HI6020IT-SSX-Y-EX models:
ATEX & IECEx Ex ia IIC T4 intrinsically safe per drawing
0594-0011 and 0594-0012 ATEX Certificate No. DEMKO
17 ATEX 1819; IECEx Certificate No. IECEx UL 17.0009
• HI6020IT and HI6020JB: USL/CNL Class I, II, III, Div 2,
Groups ABCDFG (except -EX versions)
PCB Dimensions
• 4.88" (12.38 cm) x 4.88" (12.38 cm)
• Removeable Phoenix Terminal Block
• 7 pin, 1 row, 3.5 mm pitch
Auxiliary Port for Connecting Junction Boxes
• TB6
Predrilled Hole Size
• 0.875 inches (22.2 mm)
Temp Range
• -10 to +60°C (14 to 140°F)
Max Current Consumption with Integrated Technician:
• 58mA with 4 x 350 ohm load cells
• 116mA with 8 x 350 ohm load cells
• 19mA with 4 x 1100 ohm load cells
• 38mA with 8 x 1100 ohm load cells
Max Current Consumption with Trimming Pots:
• 58mA with 4 x 350 ohm load cells
• 116mA with 8 x 350 ohm load cells
• 19mA with 4 x 1100 ohm load cells
• 38mA with 8 x 1100 ohm load cells
Power Ratings
• HI6020IT: 5 VDC, Class 2, max. 50 mA
• HI6020JB (sum card, fiberglass & painted steel):
2-15 VDC, Class 2, max. 275 mA
• HI6020JB Stainless Steel for Hazardous Areas:
5 VDC, Class 2, max. 50 mA
• HI6020IT & HI6020JB Class I, Div 1 versions:
Power must be supplied through approved
intrinsically safe barriers per control drawing
0594-0007 (HI 6020JB) or 0594-0008
(HI6020IT)
• HI6020IT & HI6020JB ATEX and IECEx versions:
Power must be supplied through approved
intrinsically safe barriers per control drawing
0594-0011 (HI6020JB) or 0594-0012
(HI6020IT)
Holes/Glands
• 5 holes (standard)
• 6 holes (for TB6 connections)
• Non ATEX/IECEx versions: Each box comes
packaged with six hole plugs and cable grip
fittings for load cell cables with an outside
diameter of .169 to 0.449 in (4.3 to 11.4 mm).
• ATEX/IECEx (-EX versions): Does not include
glands or hole plugs. For use with Intrinsic
Barriers Only
Warranty
Two-year warranty against defects in workmanship

All specifications subject to change without notice. Please contact the Hardy factory or visit our website for the latest specifications.

MODEL #           DESCRIPTION
HI6020IT-PS1: Integrated Technician NEMA 4/IP66 Painted Steel, 5 holes/6 glands, Class I, II, III Div 2
HI6020IT-FG1:
Integrated Technician NEMA 4X/IP66 Fiberglass, 5 holes/6 glands, Class I, II, III Div 2
HI6020IT-SC1: Integrated Technician Summing Card, no Enclosure
HI6020IT-PS2: Integrated Technician NEMA 4/IP66 Painted Steel with Trim Pots*, 5 holes/6 glands, Class I, II, III Div 2
HI6020IT-FG2: Integrated Technician NEMA 4X/IP66 Fiberglass with Trim Pots*, 5 holes/6 glands, Class I, II, III Div 2
HI6020IT-SC2: Integrated Technician Summing Card with Trim Pots*, no Enclosure
HI6020JB-PS1: NEMA 4/IP 66 Painted Steel, 5 holes/6 glands, Class I, II, III Div 2
HI6020JB-FG1: NEMA 4X/IP 66 Fiberglass, 5 holes/6 glands Class I, II, III Div 2
HI6020JB-SC1: Summing Card, no Enclosure
HI6020JB-PS2: NEMA 4/IP 66 Painted Steel with Trim Pots*, 5 holes/6 glands, Class I, II, III Div 2
HI6020JB-FG2: NEMA 4X Fiberglass with Trim Pots*, 5 holes/6 glands, Class I, II, III Div 2
HI6020JB-SC2: Summing Card with Trim Pots*, no Enclosure
HI6020IT-SS1: Integrated Technician Summing Card in Stainless Steel Enclosure, 5 holes/6 glands, Class I, II, III Div 1
HI6020IT-SS1-6: Integrated Technician Summing Card in Stainless Steel Enclosure, 6 holes/6 glands, Class I, II, III Div 1


HI6020IT-SS1-6-EX: Integrated Technician Summing Card in Stainless Steel Encl., 6 holes, 0 glands, ATEX, IECEx


HI6020IT-SS1-EX: Integrated Technician Summing Card in Stainless Steel Enclosure, 5 holes, 0 glands, ATEX, IECEx

HI6020IT-SS2: Integrated Technician Summing Card in Stainless Steel Enclosure with Trim Pots, 5 holes/6 glands, Class I, II, III Div 1


HI6020IT-SS2-6: Integrated Technician Summing Card in Stainless Steel Encl., w Trim Pots, 6 holes/6 glands, Class I, II, III Div 1


HI6020IT-SS2-6-EX: Integrated Technician Summing Card in SS Enclosure, 6 holes/0 glands, with Trim Pots, ATEX, IECEx


HI6020IT-SS2-EX: Integrated Technician Summing Card in SS Enclosure, with Trim Pots, 5 holes/0 glands, ATEX, IECEx


HI6020JB-SS1: Summing Card in Stainless Steel Enclosure, 5 holes/6 glands, Class I, II, III Div 1


HI6020JB-SS1-6: Summing Card in Stainless Steel Enclosure, 6 holes/6 glands, Class I, II, III Div 1


HI6020JB-SS1-6-EX: Summing Card in Stainless Steel Enclosure, 6 holes/0 glands,, ATEX, IECEx


HI6020JB-SS1-EX: Summing Card in Stainless Steel Enclosure, 5 holes, 0 glands, ATEX, IECEx


HI6020JB-SS2: Summing Card in Stainless Steel Enclosure with Trim Pots, 5 holes/6 glands, Class I, II, III Div 1

HI6020JB-SS2-6: Summing Card in Stainless Steel Enclosure, with Trim Pots, 6 holes/6 glands, Class I, II, III Div 1


HI6020JB-SS2-6-EX:
Summing Card in SS Enclosure, with Trim Pots, 6 holes, 0 glands, ATEX, IECEx