p: 800-821-5831 / +1-858-278-2900 / email: hardyinfo@hardysolutions.com / Online Support
Hardy Process Solutions
  Give Us Feedback
 
Home > Process Weighing > C2® Electronic Calibration

C2® Electronic Calibration

Hardy's C2® core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

The HARDY C2® Difference

FAST                                                                                                                                                                                    
• Calibrates with ONE reference point, not FIVE
SAFE
• Eliminates need for full-scale test weights
RELIABLE
• Data stored in chip

What is C2® Electronic Calibration?
Since 1994, thousands of weighing systems have been calibrated electronically using C2® Electronic Calibration by Hardy Process Solutions. Unlike calibration with test weights, all the live weight on the scale does not have to be removed and heavy test weights do not have to be repeatedly put on and off the scale. As soon as your scale system is installed, it can be C2 calibrated, and proper scale installation verified. The result is a calibration that is easier, quicker, safer, and typically more accurate than methods used in the past.

What is a C2 system?
A C2 system includes load points, junction box, cabling and instrumentation, and is designed to make calibration easier than ever before. Upon installation or re-calibration, your Hardy instrument automatically searches for C2 certified load points and records their performance characteristics. Entering a reference point is all that’s needed to bring your system on-line within seconds. On instruments with “THE BUTTON” feature, one touch of a button is enough. All that’s left is to verify your scale. This is done by carefully distributing one or two small weights (25 to 100 lbs.) on to the scale so they are shared by all the load sensors. The scale reading should equal the value of the test weight/s applied. Remove the weight/s and the scale reading should return to its original value. If both of these are true then the scale is calibrated, verified and ready for use! If the values are not true, then there are mechanical problems with the scale that need to be corrected.
 
Is C2 Electronic Calibration as accurate as calibration with test weights?
Theoretically, test weights should provide an accurate calibration within the quality of the scale installation. However, calibration conditions are often less than ideal. Many vessels lack the space needed to place enough test weights on them to get an accurate calibration. Distributing the weights equally on the vessel may also be impossible. Some vessels are mounted in areas offering limited accessibility, while others have weight capacities far in excess of available test weights. These real world issues often cause calibration errors.

With C2, these considerations are no longer an issue. Each individual load sensor has its performance characteristics stored on an internal memory device. These characteristics are measured on National Institute of Standards and Technology (NIST) traceable test devices and electronically recorded when the sensor is manufactured. The C2 system uses these parameters, the instruments’ characteristics and a reference point to calibrate the scale system.

C2 reduces downtime for repairs and time waiting for test weights. It eliminates test weight related injuries and ends material substitution headaches, including contamination and waste disposal issues. C2 is a standard feature on Hardy load sensors, weigh modules, and weight and rate controllers.

View Video on C2


 

 

 

Request more info from Hardy

C2® Electronic Calibration Products

HI 1756-WS Accessories

HI 1746-WS Weigh Scale Module

HI 1771-WS Weigh Scale Module

ADVANTAGE® Weigh Modules-HLPT

C2® Cable

HI 200DNWM DeviceNet Weigh Module

HI 2110-WI Weight Indicator

IT® Junction Box

Standard Junction Box

ADVANTAGE® Weigh Modules-LPRC03

ADVANTAGE® Weigh Modules-LPRA

HI 2160RCPlus Rate Controller

ADVANTAGE® LITE Weigh Modules

ADVANTAGE® Weigh Modules-LPB

HI 1756-WS ControlLogix® Weigh Module

HI 1756-2WS ControlLogix Weigh Scale Module

HI 1769-2WS CompactLogix® Module

HI 1769-WS CompactLogix® Module

ANY-WEIGH® Bench Scales

ANY-WEIGH® Floor Scales

HI 3010 Filler / Dispenser Controller

HI 2151/30WC Weight Controller

ADVANTAGE® Weigh Modules-HLPS

HI 3030 Weight Controller

HI 4050 Weight Controller

HI 4060 Rate Controller

HI 1756-FC ControlLogix Weigh Feeder Control Module

HI 1769-FC CompactLogix and MicroLogix Weigh Feeder Control Module

Single Point Load Cells

HI 1756-nDF ControlLogix Dispenser/Filler Module

HI 4050CW Check Weighing Bundle


Hardy Process Solutions, Inc.
9440 Carroll Park Drive - Suite 150
San Diego, CA 92121 USA
+1.858.278.2900
800.821.5831
Fax +1.858.278.6700
Copyright© 2012 Hardy Process Solutions, Inc.
All Rights Reserved.
Contact Us / Webmaster / Privacy Statement / SiteMap